Follow us :

Tablet dedust Machine

publisherSteve

time2022/01/06

Tablet dedust Machine

Q1The difference between vibration sifter and tablet dedust machine.

AThe vibrating sifter is used for powder screening, and the tablet dedust machine is used for tablet cleaning.

 

Q2The tablet dedust machine is divided into up-spin and down-spin? What is the difference?

ATop spin: the material goes in from the bottom and goes out from the top.

Down spin: the material comes in from the top and comes out from the bottom. The top spinning speed is fast, the price is more expensive.

 

Q3The function of vibration sifter.

AThrough the sieve of different meshes, particles of different sizes are sorted and classified to prepare for tableting.

 

Q4Can the vibration sifter have only one outlet?

ANo, the purpose of the machine is to classify different particles. Making one outlet cannot achieve this purpose. At least two outlets are required.

 

Q5How to divide the mesh of the tablet dedust machine? Can a machine have two mesh sizes?

ATablet dedust does not divide the mesh number, and the channel is spiral.

 

Q6Is there a hopper on the tablet dedust machine? Can it be customized?

AGenerally, the feed port of the tablet dedust machine is set directly upstream of the equipment discharge port, and the fixed problem of the customized hopper needs to be considered.

 

Q7What are the maximum and minimum meshes that the tablet dedust machine can withstand?

AThe maximum mesh number of ordinary sieves is 200, and the minimum is unlimited.

 

Q8Is the speed of the gold inspection machine constant?

AConstant speed means that the speed is set to a certain speed and cannot be changed. This speed is calculated based on the output. Set the speed of the whole machine as a fixed speed in meters per minute. If the speed is adjusted, the speed-adjustable frequency converter needs to be added, which will increase the cost.

 

Q9Apart from Fe, NOFe, Sus304, are there other metals detected by the gold inspection machine?

ACopper, aluminum, etc.

 

Q10Golden inspection machine mentioned: 52 kinds of products can be stored and recorded, is it equivalent to having a traceability function?

ANo, the testing standards of different products are different. The testing standards of 52 different products can be saved. This time, when testing product A, set the testing standards of product A. Next time testing product A, you can test if you find this record.

 

Q11Gold inspection machine: Just need the diameter and height of the largest bottle, or do you still need the diameter and height of the smallest bottle? The higher the detection height and width, the lower the sensitivity. For the same machine, for example, the current detection is 200 (width) * 200 (height). Within this range, is the gold inspection machine more effective in detecting large bottles than in small boxes?

AIn the same detection range, the detection effect is the same, and the size of the bottle is the same. unless the characteristics of the product are different, the detection effect is different. Conventionally, the largest and smallest bottle sizes need to be provided, because we will consider which model is more suitable.

The detection accuracy of the metal inspection machine is determined by the size of the detection channel opening, the larger the opening, the worse the effect.

1. The maximum diameter of the bottle is 100mm and the height is 180mm. The minimum diameter is 60mm and the height is 80mm.

2. There are 2 types of options:

One: You can choose a gold inspection machine suitable for all sizes to inspect all bottles.

Two: You can choose two types of gold inspection machines to inspect bottles of different sizes.

3. Those who do not require high detection accuracy and do not want to spend more money can choose to use a general-purpose gold inspection machine.

4. The universal gold inspection machine detects all bottles, which will reduce the accuracy of detecting small bottles. If you want high accuracy, you can also choose a gold inspection machine with better effect. As long as the products in all bottles are the same, the detection results will be similar.

 

Q12What is the difference between a vertical colloid mill and a split colloid mill?

ASplit colloid mill, the heat generated during work does not interfere with each other, which is convenient for long-time work.

Vertical colloid mills are suitable for low-volume, experimental factories, but the heat generated by the motor and the heat generated by the gear will cross each other, which is easy to cause the motor to generate heat.

 

Q13What is the difference between a vertical colloid mill and a split colloid mill?

ASplit colloid mill, the heat generated during work does not interfere with each other, which is convenient for long-time work.

Vertical colloid mills are suitable for low-volume, experimental factories, but the heat generated by the motor and the heat generated by the gear will cross each other, which is easy to cause the motor to generate heat.

The vertical type is recommended for handling general fluid materials, and the split type can be used for handling fluids and colloids or materials with viscosity or consistency.

 

Q14What is the difference between single cooling colloid mill and double cooling colloid mill?

AThere is no difference in mechanical performance, and the methods of use and operation are different. Single cooling is easy to maintain, double cooling is difficult to maintain. Single cooling is an improvement on the basis of dual cooling.